logo
Eco-Tech Suzhou Limited
Email Melisss.Zhao@eco-techsz.com TEL: 86-- 18626217683
Home > products > ABB Pressure Transmitter >
266AST ABB Pressure Transmitter Absolute Pressure Transmitter
  • 266AST ABB Pressure Transmitter Absolute Pressure Transmitter
  • 266AST ABB Pressure Transmitter Absolute Pressure Transmitter
  • 266AST ABB Pressure Transmitter Absolute Pressure Transmitter

266AST ABB Pressure Transmitter Absolute Pressure Transmitter

Brand Name ABB
Model Number 266AST
Document Product Brochure PDF
Product Details
Customized Support:
OEM
Mounting Bracket:
316 Stainless Steel
Supply Voltage Effect:
0.005% Span Per Volt
Output Signal:
4~20mA
Measurement Range:
0.1...0..100MPA
Power Supply:
24VDC
Operating Temperature:
40~85℃
Electrical Output Signal:
DC 0 ... 10
Highlight: 

266AST ABB Pressure Transmitter

,

ABB Pressure Transmitter 266AST

,

20ma Absolute Pressure Transmitter

Product Description

Absolute pressure transmitter 266AST

Model 266AST is the top performance absolute pressure transmitter suitable for liquid, gas or steam applications. It provides a broad selection of options, such as fill fluids and wetted materials, allowing operation even with critical process media at harsh environment. Long-term stability and proven reliability are the key-factors of 266AST.

 

Overview

In addition to the plug-in terminal block, this transmitter features in-field replaceable electronics module that thanks to the auto-configuration functionality dramatically improves plant productivity. Its intuitive plug-and-play display with easy setup procedure really helps users by saving time and lowering maintenance and inventory costs. Moreover, the innovative TTG (Through The Glass) technology allows users to configure the instruments in the field without removing the windowed front cover and consequently to save a lot of time.

The 266AST is certified by TUV NORD for use in safety instrumented systems as per the requirements of IEC61508. The transmitters meet the requirements for SIL2 applications in a single transmitter configuration (1oo1) and for SIL3 applications in a redundant configuration (1oo2).

Data

  • Base accuracy : ± 0.04 %
  • Span limits: 0.3 ... 10000 kPa abs.; 2.25 mmHG ... 1450 psia
  • Output signal: Multiple protocol availability offering interchangeability and transmitter upgrade capabilities
    – 4 to 20 mA, HART
    – PROFIBUS PA 3.01
    – FOUNDATION Fieldbus ITK 6.x
  • Local operation with LCD with TTG (Through The Glass) technology without the need of opening the housing
  • Conforms to SIL2 / SIL3 acc. to IEC 61508
  • Full compliance with PED Category III